Brother Drum Counter Reset for DR251 Units – HL version

After replacing the drum units DR251CL in your HL3150CDN and HL3170CDW colour laser printer you’ll have to reset the page counter. The following steps are the procedure to perform the counter reset… Turn the printer power switch on. Press “Up“ key while holding down the “Go” button. Use the up or down key to select Drum…

Brother Drum Counter Reset for DR251 Units – MFC version

After replacing the drum units DR251CL in your MFC9140CDN MFC9330CDW and MFC9340CDW colour laser printer you’ll have to reset the page counter. The following steps are the procedure to perform the counter reset Turn the printer power switch on. Press “Settings“. Press “All Settings“. Scroll up or down by swiping or using the arrow keys to“Machine…

Kyocera FS-1010 dirty print – How to fix

Hi If you have a Kyocera Ecosys FS1000, Ecosys FS-1000+, Ecosys FS1010 or Ecosys FS-1010+ laser print that has dirty prints like the sample shown below you have a worn/old drum cleaning blade. To fix this fault you will need to replace the blade with a new one. You may also note that the printing…

DR2025 Drum Counter Reset – HL2040 HL2030 HL2070

Replaced the DR2025 Drum on your Brother printer and the light doesn’t  go out? That’s because you have to reset the drum counter when you replace the drum unit. To reset the counter on your new drum unit for HL-2040 HL-2030 HL-2070 please follow the procedure listed below. Turn printer on if it isn’t already.…